• CSPF: 3.47

Daikin Ceiling Suspended AC FHNQ18MV1 (2.0Hp)

Listed price 23.687.000
Price20.150.000
( VAT included )
Saving 3.537.000
  • The selling price includes VAT and is committed to a genuine 100 percent NEW-WARRANTY NATIONWIDE.
  • Free delivery within Ho Chi Minh City-fast installation, overtime installation as required. Support delivery and installation in the province.
Specifications
Made in Thương hiệu : Nhật - Sản xuất tại : Thái Lan
Refrigerant R410A
Type Không inverter (không tiết kiệm điện) - loại 1 chiều (chỉ làm lạnh)
Cooling Capacity 2.0 Hp (2.0 Ngựa) - 18.000 Btu/h
Use For Room Diện tích 24 - 27 m² hoặc 72 - 81 m³ khí (thích hợp cho phòng khách, văn phòng)
Power Input (Ph/V/Hz) 1 Pha, 220 - 240 V, 50Hz
Power consumption (kW) 2,04 Kw
Refrigerant/ Liquid Pipe Diameter (mm) 6.4 / 12.7
Maximum Pipe Length 30 (m)
Maximum Elevation Length 15 (m)
Cooling Seasonal Performance Factor (CSPF) 3.47
Indoor Unit
Indoor Unit Model FHNQ18MV1
Indoor Unit Dimensions (mm) 195 x 1.160 x 680 (mm)
Indoor Unit Net Weight (Kg) 26 (kg)
Outdoor Unit
Outdoor Unit Model RNQ18MV1
Outdoor Unit Dimensions (mm) 595 x 845 x 300 (mm)
Outdoor Unit Net Weight (Kg) 40 (kg)
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Product Description

Anti-Corrosion Treatment for Outdoor Unit Heat Exchanger

To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.

Easy Installation and Maintenance

Pre charged for up to 15 m (Applies to RNQ30-48M)
4-direction piping offers greater layout freedom (Applies to RNQ30-48M).

Quiet Operation

Depending on types of indoor units, sound level can range from
32 dB(A) to 45 dB(A). Outdoor unit operation sound is from 
48 dB(A) to 58 dB(A).
This data is based on “Examples of Sound Levels”, Ministry of the Environment, Japan, November 12, 2002.

Diffuses comfortable air throughout the room

  • Auto-swing (up&down) brings comfort to the room.

  • Wide air discharge openings produce a spreading 100° airflow

  • Air is blown up to 50° in the downward direction.

  • Installable on ceilings 3.5 m high

  • Switchable fan speed: High/Low

  • Programme "Dry"

 

Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature

Installation flexibility for freedom of design

  • Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints
 Indoor unit  3M 18/21M 26/30M 36/42/48M
 Height 195
 Width 960 1,160 1,400 1,590
 Depth 680
  • Flexible installation
    The unit fits more snugly into tight spaces. 
    *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case.
  • All wiring and internal servicing can be done from under the unit
  • Pipes more easily rigged
    Plastic cover is used to conceal piping work holes.
    When piping work the cover is easily taken off, and after piping work easily attached again to conceal the holes.

Quiet operation

Sound operation has been reduced on the exposed ceiling suspended type unit.

Indoor unit High Low
13M 43 39
18/21M 44 40
26/30M 45 40
36/42M 48 42
48M 49 43

Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Easier to maintain

  • Long-life filter lasts about 1 year*
    * For dust concentration of 0.15 mg/m3
    Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).
  • Non-flocking flap
    Condensation does not easily form on and dirt does not cling to non-flocking flap. It is easy to clean.
  • Easy-clean, flat surfaces
    It is easy to wipe dirt off the flat side and lower surfaces of the unit.
  • For all maintenance tasks, access is from bottom surface.

Oil resistant grille

  • Oil-resistant plastic is used for the air suction grille.
    This satisfies durability in restaurants and other similar environments.

Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.

  13 18 21 26
Model Name Indoor Unit FHNQ13MV1 FHNQ18MV1 FHNQ21MV1 FHNQ26MV1
Outdoor Unit V1 RNQ13MV1 RNQ18MV1 RNQ21MV1 RNQ26MV1
Y1 - - - RNQ26MY1
 Cooling Capacity*1,2  kW 3.8 5.3 6.2 7.6
 Btu/h 13,000 18,000 21,000 26,000
 Power Consumption  Cooling*1  kW 1.58 2.04 2.38 2.65
 COP   W/W 2.4 2.6 2.6 2.87
 Indoor Unit  Sound Level (H/L) (220 V)*3  dB(A) 43/39 44/40 45/40
 Dimensions (H x W x D)  mm 195 x 960 x 680 195 x 1,160 x 680 195 x 1,400 x 680
 Outdoor Unit  Sound Level*4 Cooling  dB(A) 49 51 52 54
 Dimensions (H x W x D)  mm 550 x 765 x 285 595 x 845 x 300 735 x 825 x 300

 

Note:
*1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
*2Capacities are net, including a deduction for cooling for indoor fan motor heat.
*3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
*4In case of MV1: 220V, MY1: 380V.