Specifications
Made in Brand of: Japan - Manufactures: Thailand
Refrigerant R-410A
Type Inverter (save energy) - two-way (cooling/heating).
Cooling Capacity 3.5 Hp - 30,700 Btu/h - 9.0 kW
Heating Capacity 9.0 ( 1.5 ~ 9.0 ) kW
Use For Room Area 40 - 45 m² or 120 - 135 m³ (suitable for living room, office...)
Power Input (Ph/V/Hz) 1 Phase 220 - 240 V, 50Hz
Power consumption (kW) 2.69 / 2.25 KW
Refrigerant/ Liquid Pipe Diameter (mm) 6.35 / 15.88
Maximum Pipe Length 30 m
Maximum Elevation Length 20 m
Indoor Unit
Indoor Unit Model FDUM100VF2
Indoor Unit Dimensions (mm) 280 x 1,370 x 740 mm
Indoor Unit Net Weight (Kg) 54 kg
Outdoor Unit
Outdoor Unit Model FDC90VNP1
Outdoor Unit Dimensions (mm) 750 x 880 x 340 mm
Outdoor Unit Net Weight (Kg) 57 kg
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Product Description

Thin design

Mitsubishi Heavy duct connected air conditioner inverter FDUM100VF2 - FDC90VNP (3.5Hp) with compact design only 280mm can easily install in any different space. Especially areas with low ceilings.

Automatic external static pressure (E.S.P)

You can set external static pressure (E.S.P) by method of manual setting on remote control.

 

The outdoor unit is compact in design

Usage of lead-free welding products, compliance with RoHS requirements, environmental protection 

To prevent exposure to the global environment, all kinds of our products have used lead-free solder alloy content in manufacturing. Include six types of toxic chemicals that we do not use, including Pb, Hg, Cd, Cr6+, PBB, PBDE added to the RoHS standard in the European (EU) markets as of July 1 / 2006.

In Vietnam, according to Circular No. 30/2011/TT-BCT of 10/08/2011, which governs the allowable levels of hazardous chemicals in electrical, electronic products and the appendix to 6 forms of chemicals above.

Mitsubishi Heavy Industries implemented by the RoHS standard do not use six toxic chemicals equal to IEC 62321 according to Decision No. 4693/QD-BCT (Circular No. 30/2011/TT-BCT) for All Mitsubishi Heavy Industries brand air conditioners on the Vietnam market.

Seer & SCOP higher

Although the nominal efficiency is lower than that of the Hyper Inverter type, SEER & SCOP is higher by optimum control.

Easy to transport and install

New control of inverter (Vector control) 

The new inverter control technology is based on vector control technology, providing the highest operating efficiency: 

-Quiet operation from low to high speed. 

-Achieve smooth variations in sinusoidal voltage. 

- Energy efficiency is significantly in the low-speed range.

Improved maintenance space

The propeller and the fan engine can separate from the right side of the indoor machine. Maintenance can conduct from the right side or the bottom of the unit.

Improved installation capacity

Drain pump installed with pipe lift of 600mm. The indoor unit has hidden under the ceiling, suitable for luxurious interior space.

Window inspections window

When the drain pan is dirty, you can easily check it through this transparent window without having to remove the drain.

Filters and control system (optional)

Technical specification

 

When you choose the powerful-Hi mode
 Noise level:125VSAPVF 36dB(A), 140VSAPVF1 38dB(A), 200VSAPVF2 44dB(A), 250VSAPVF 45dB(A), 140VSTVF 37dB(A), 200VSATVF1 38dB(A), 71VNPVF1 38dB(A), 90VNPVF2 44dB(A), 100VNP1VF2 44dB(A)
Air flow: 125VSAPVF 20m3/min, 140VSAPVF1 24m3/min, 200VSAPVF2 36m3/min, 250VSAPVF 39m3 /min, 140VSTVF 13m3/min, 200VSATVF1 24m3/min, 71VNPVF1 24m3/min, 90VN PVF2 36m3/min, 100VNP1VF2 36m3/min
Note:
 Parameters are measure under conditions (IOS-T1)
 Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. By 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.

* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions
** Indicators only apply when operating one indoor unit
*** Static pressure can change by setting on the controller. The maximum static pressure on "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa**** If cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.