Thin design
Mitsubishi Heavy duct connected air conditioner inverter FDUM50VF - SRC50ZSX-S (2.0Hp) with compact design only 280mm can easily install in any different space.
Automatic external static pressure (E.S.P)
You can set external static pressure (E.S.P) by method of manual setting on remote control.
Hyper Inverter technology saves energy effectively
The outdoor unit integrated with modern advanced technology with high efficiency, efficient heating operation, and the ability to connect long pipes. Contribute to environmental conservation by saving electricity, allowing installation of the devices (4 ~ 6HP) can be heated to-20oC under ambient temperature conditions. The flexible design has improved for pipe lengths of up to 100m.
Copper tube length - 100m (hyper inverter 4-6hp)
Length of the preloaded gas pipeline up to 30m
The volume of pre-charged cold gas for the pipeline is up to 30m in length. It helps to minimize the need to add refrigerant on site, avoid overcharging or lack of gas, make installation easy and quick.
* Applying Hyper Inverter models 1.5 ~ 2.5HP, Standard Inverter is 15m.
Monitoring of functions
Equipped with RS232C for the direct link to a personal computer, our service program is easy to control and run ('Mente PC').
Improved maintenance space
The propeller and the fan engine can separate from the right side of the indoor machine. Maintenance can conduct from the right side or the bottom of the unit.
Improved installation capacity
Drain pump installed with pipe lift of 600mm. The indoor unit has hidden under the ceiling, suitable for luxurious interior space.
Window inspections window
When the drain pan is dirty, you can easily check it through this transparent window without having to remove the drain.
Filters and control system (optional)
Technical specification
When you choose the powerful-Hi mode
Noise level: 40/50ZSXVF 37dB(A), 60ZSXVF 36dB(A), 71VNXVF1 38dB(A), 100VN(S)XVF2 44dB(A), 125VN(S)XVF 45dB(A), 140VN(S)XVF 47dB(A)
Air flow: 40/50ZSXVF 13m3/min, 60ZSXVF 20mm3/min, 71VNXVF1 24m3/min, 100VN(S)XVF2 36m3/min, 125VN(S)XVF 39m3/min, 140VN(S)XVF 48m3/min.
Note:
Parameters are measure under conditions (IOS-T1)
Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. By 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.
* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions
** Static pressure can change by setting on the controller. The maximum static pressure on "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa
**** If cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.